Enquire Now

FHQ Series

COOLING ONLY & HEAT PUMP

Upgrade to a compact and quite air conditioning system that is designed keeping in today’s scenario. Its wide air discharge vents generate spreading 100 degree airflow for maximum comfort. Designed to fit in tight spaces, these units are an ideal solution for both commercial as well as residential air conditioning needs.

Power Supply:

Product category:

Available in (kW):

Specification

Ceiling Suspended Type (Cooling Only)

inverter-r410
Model nameIndoor unitFHQ125BVV1BFHQ100BVV1BFHQ125BVV1B
Outdoor unitRZR125LVVM6RZR100LUY1RZR125LUY1
Power supply1 Phase, 220-240 V, 50 Hz3 Phase, 380-415 V, 50 Hz3 Phase, 380-415 V, 50 Hz
Cooling capacity Rated  (min.~max.)kW12.5 (5.7-14.0)10.0 (5.0-11.2)12.5 (5.7-14.0)
Power consumptionCooling RatedkW4.5503.5104.550
Annual Power consumptionkWhNANANA
ISEER / StarWh/WhNANANA
Indoor unit
ColourWhiteWhiteWhite
Airflow rate (H/L)m3/min30/2524/2030/25
cfm1059/883847/7061059/883
Sound level (H/L)dB(A)44/3942/3744/39
Dimensions HxWxDUnitmm195x1590x680195x1400x680195x1590x680
PanelmmNANANA
Machine weightUnitkg353235
PanelkgNANANA
certified operation range°CDB14 to 2514 to 2514 to 25
Outdoor unit
Colourlvory Whitelvory Whitelvory White
CompressorType Hermetically Sealed Scroll TypeHermetically Sealed Scroll TypeHermetically Sealed Scroll Type
Motor outputkW2.62.12.6
Refrigerant charge (R-410A)kg3.7 (Charged For 30m)2.7 (Charged For 30m)3.7 (Charged For 30m)
Sound levelCoolingdB(A)504950
Dimensions (HxWxD)mm1170x900x3201170x900x3201170x900x320
Machine weightkg979297
Certified operation range°CDB21 to 4621 to 4621 to 46
Piping connectionsLiquid (Flare)mmø 9.5ø 9.5ø 9.5
Gas (Flare)mmø 15.9ø 15.9ø 15.9
DrainmmVP20 (I.D ø20, O,D ø26)VP20 (I.D ø20, O,D ø26)VP20 (I.D ø20, O,D ø26)
Max. interunit piping lengthm50 (Equivalent length 70)50 (Equivalent length 70)50 (Equivalent length 70)
Max. installation level differencem303030

Note :

  • Rated cooling capacities are based on the following conditions; Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat heigher owing to ambient conditions.

Ceiling Suspended Type (Heat Pump)

inverter-r410
Model nameIndoor unitFHQ125BVV1BFHQ100BVV1BFHQ125BVV1B
Outdoor unitRZQ125KCV4ARZQ100HAY4ARZQ125HAY4A
Power supply1 Phase, 240 V, 50 Hz3 Phase, 415 V, 50 Hz3 Phase, 415 V, 50 Hz
Cooling capacity Rated  (min.~max.)kW11.2 (5.7-14.0)9.2 (5.0-11.2)11.2 (5.7-14.0)
Heating capacity Rated  (min.~max.)kW13.5 (6.0-16.2)10.5 (5.1-12.8)13.5 (6.0-16.2)
Power consumptionCooling RatedkW3.7002.8503.550
Power consumptionHeating RatedkW4.3503.2604.350
Annual Power consumptionkWhNANANA
ISEER / StarWh/WhNANANA
Indoor unit
ColourWhiteWhiteWhite
Airflow rate (H/L)m³/min30/2524/2030/25
cfm1059/883847/7061059/883
Sound level (H/L) dB(A)44/3942/3744/39
Dimensions HxWxDUnitmm195x1590x680195x1400x680195x1590x680
PanelmmNANANA
Machine weightUnitkg353235
PanelkgNANANA
certified operation range°CDB14 to 2514 to 2514 to 25
Outdoor unit
Colourlvory Whitelvory Whitelvory White
CompressorType Hermetically Sealed Scroll TypeHermetically Sealed Scroll TypeHermetically Sealed Scroll Type
Motor outputkW2.42.32.7
Refrigerant charge (R-410A)kg3.7 (Charged For 30m)4.3 (Charged For 30m)4.3 (Charged For 30m)
Sound levelCooling/ HeatingdB(A)50/5249/5150/52
Dimensions (HxWxD)mm1170x900x3201345x900x3201345x900x320
Machine weightkg98108108
Certified operation rangeCooling°CDB-5 to 46-5 to 46-5 to 46
Certified operation rangeHeating°CWB-15 to 15.5-15 to 15.5-15 to 15.5
Piping connectionsLiquid (Flare)mmø 9.5ø 9.5ø 9.5
Gas (Flare)mmø 15.9ø 15.9ø 15.9
DrainmmVP20 (I.D ø20, O,D ø26)VP20 (I.D ø20, O,D ø26)VP20 (I.D ø20, O,D ø26)
Max. interunit piping lengthm75 (Equivalent length 90m)75 (Equivalent length 90m)75 (Equivalent length 90m)
Max. installation level differencem303030

Note :

  • Rated cooling capacities are based on the following conditions; Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Rated heating capacities are based on the following conditions; Indoor temp., 20°CDB, outdoor temp. 7°CDB. 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat heigher owing to ambient conditions.

Ceiling Suspended Type

inverter-r410
Name of optionRemarkKit name
FHQ100BVV1BFHQ125BVV1B
Replacement long-life filterResin netKAF501DA112KAF501DA160
Drain-up kit  KDU50N125VE
L-type piping kit (for upward direction)  KHFP5MA160
Remote controllerWireless typeCooling onlyBRC7EA66
heat pumpBRC7EA63W
Wired type1 BRC1C61
Wired LCD remote controller with weekly schedule timer1  BRC1D61
Navigation Remote ControllerWired type1 BRC1E61
Central remote controller2  DCS302CA61
Unified ON/OFF controller2  DCS301BA61
Schedule timer2  DST301BA61
Touch Controller2  DCS601C51
Adaptor for wiring  KRP1BA54
Wiring adaptor for electrical appendices3  KRP4AA52
Interface adaptor for SkyAir series  DTA112BA51
Installation box for adaptor PCB  KRP1CA93
Remote sensor (for indoor temperature)  KRCS01-1B
Electical box with earth terminal (3 blocks)  KJB311AA
Electical box with earth terminal (2 blocks)  KJB212AA

Note :

  • 1. Wiring for wired remote controller to be procured locally.
  • 2. This optional accessory requires DTA112BA51.
  • 3. Installation box for adaptor PCB (KRP1CA93) is necessary.

AS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.

Customer Support Information: Give A Missed Call: @ 9210188999, Call Our Customer Contact Centre: 011-40319300or Write To Us at: customerservice@daikinindia.com