Skip to main content
Enquire Now

FHQ Series

COOLING ONLY & HEAT PUMP

FHQ Series

fhq series

Upgrade to a compact and quite air conditioning system that is designed keeping in today’s scenario. Its wide air discharge vents generate spreading 100 degree airflow for maximum comfort. Designed to fit in tight spaces, these units are an ideal solution for both commercial as well as residential air conditioning needs.

Power Supply
Product Category

Available in (kW):

Specification

Ceiling Suspended Type (Cooling Only)

inverter-r410
Model name Indoor unit FHQ125BVV1B FHQ100BVV1B FHQ125BVV1B
Outdoor unit RZR125LVVM6 RZR100LUY1 RZR125LUY1
Power supply 1 Phase, 220-240 V, 50 Hz 3 Phase, 380-415 V, 50 Hz 3 Phase, 380-415 V, 50 Hz
Cooling capacity Rated  (min.~max.) kW 12.5 (5.7-14.0) 10.0 (5.0-11.2) 12.5 (5.7-14.0)
Power consumption Cooling Rated kW 4.550 3.510 4.550
Annual Power consumption kWh NA NA NA
ISEER / Star Wh/Wh NA NA NA
Indoor unit
Colour White White White
Airflow rate (H/L) m3/min 30/25 24/20 30/25
cfm 1059/883 847/706 1059/883
Sound level (H/L) dB(A) 44/39 42/37 44/39
Dimensions HxWxD Unit mm 195x1590x680 195x1400x680 195x1590x680
Panel mm NA NA NA
Machine weight Unit kg 35 32 35
Panel kg NA NA NA
certified operation range °CDB 14 to 25 14 to 25 14 to 25
Outdoor unit
Colour lvory White lvory White lvory White
Compressor Type   Hermetically Sealed Scroll Type Hermetically Sealed Scroll Type Hermetically Sealed Scroll Type
Motor output kW 2.6 2.1 2.6
Refrigerant charge (R-410A) kg 3.7 (Charged For 30m) 2.7 (Charged For 30m) 3.7 (Charged For 30m)
Sound level Cooling dB(A) 50 49 50
Dimensions (HxWxD) mm 1170x900x320 1170x900x320 1170x900x320
Machine weight kg 97 92 97
Certified operation range °CDB 21 to 46 21 to 46 21 to 46
Piping connections Liquid (Flare) mm ø 9.5 ø 9.5 ø 9.5
Gas (Flare) mm ø 15.9 ø 15.9 ø 15.9
Drain mm VP20 (I.D ø20, O,D ø26) VP20 (I.D ø20, O,D ø26) VP20 (I.D ø20, O,D ø26)
Max. interunit piping length m 50 (Equivalent length 70) 50 (Equivalent length 70) 50 (Equivalent length 70)
Max. installation level difference m 30 30 30

Note :

  • Rated cooling capacities are based on the following conditions; Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat heigher owing to ambient conditions.

Ceiling Suspended Type (Heat Pump)

inverter-r410
Model name Indoor unit FHQ125BVV1B FHQ100BVV1B FHQ125BVV1B
Outdoor unit RZQ125KCV4A RZQ100HAY4A RZQ125HAY4A
Power supply 1 Phase, 240 V, 50 Hz 3 Phase, 415 V, 50 Hz 3 Phase, 415 V, 50 Hz
Cooling capacity Rated  (min.~max.) kW 11.2 (5.7-14.0) 9.2 (5.0-11.2) 11.2 (5.7-14.0)
Heating capacity Rated  (min.~max.) kW 13.5 (6.0-16.2) 10.5 (5.1-12.8) 13.5 (6.0-16.2)
Power consumption Cooling Rated kW 3.700 2.850 3.550
Power consumption Heating Rated kW 4.350 3.260 4.350
Annual Power consumption kWh NA NA NA
ISEER / Star Wh/Wh NA NA NA
Indoor unit
Colour White White White
Airflow rate (H/L) m³/min 30/25 24/20 30/25
cfm 1059/883 847/706 1059/883
Sound level (H/L)   dB(A) 44/39 42/37 44/39
Dimensions HxWxD Unit mm 195x1590x680 195x1400x680 195x1590x680
Panel mm NA NA NA
Machine weight Unit kg 35 32 35
Panel kg NA NA NA
certified operation range °CDB 14 to 25 14 to 25 14 to 25
Outdoor unit
Colour lvory White lvory White lvory White
Compressor Type   Hermetically Sealed Scroll Type Hermetically Sealed Scroll Type Hermetically Sealed Scroll Type
Motor output kW 2.4 2.3 2.7
Refrigerant charge (R-410A) kg 3.7 (Charged For 30m) 4.3 (Charged For 30m) 4.3 (Charged For 30m)
Sound level Cooling/ Heating dB(A) 50/52 49/51 50/52
Dimensions (HxWxD) mm 1170x900x320 1345x900x320 1345x900x320
Machine weight kg 98 108 108
Certified operation range Cooling °CDB -5 to 46 -5 to 46 -5 to 46
Certified operation range Heating °CWB -15 to 15.5 -15 to 15.5 -15 to 15.5
Piping connections Liquid (Flare) mm ø 9.5 ø 9.5 ø 9.5
Gas (Flare) mm ø 15.9 ø 15.9 ø 15.9
Drain mm VP20 (I.D ø20, O,D ø26) VP20 (I.D ø20, O,D ø26) VP20 (I.D ø20, O,D ø26)
Max. interunit piping length m 75 (Equivalent length 90m) 75 (Equivalent length 90m) 75 (Equivalent length 90m)
Max. installation level difference m 30 30 30

Note :

  • Rated cooling capacities are based on the following conditions; Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Rated heating capacities are based on the following conditions; Indoor temp., 20°CDB, outdoor temp. 7°CDB. 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat heigher owing to ambient conditions.

Ceiling Suspended Type

inverter-r410
Name of option Remark Kit name
FHQ100BVV1B FHQ125BVV1B
Replacement long-life filter Resin net KAF501DA112 KAF501DA160
Drain-up kit     KDU50N125VE
L-type piping kit (for upward direction)     KHFP5MA160
Remote controller Wireless type Cooling only BRC7EA66
heat pump BRC7EA63W
Wired type1   BRC1C61
Wired LCD remote controller with weekly schedule timer1     BRC1D61
Navigation Remote Controller Wired type1   BRC1E61
Central remote controller2     DCS302CA61
Unified ON/OFF controller2     DCS301BA61
Schedule timer2     DST301BA61
Touch Controller2     DCS601C51
Adaptor for wiring     KRP1BA54
Wiring adaptor for electrical appendices3     KRP4AA52
Interface adaptor for SkyAir series     DTA112BA51
Installation box for adaptor PCB     KRP1CA93
Remote sensor (for indoor temperature)     KRCS01-1B
Electical box with earth terminal (3 blocks)     KJB311AA
Electical box with earth terminal (2 blocks)     KJB212AA

Note :

  • 1. Wiring for wired remote controller to be procured locally.
  • 2. This optional accessory requires DTA112BA51.
  • 3. Installation box for adaptor PCB (KRP1CA93) is necessary.

AS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.

Customer Support Information: Give A Missed Call: @ 9210188999, Call Our Customer Contact Centre: 011-40319300 / 1860 180 3900 or Write To Us at: customerservice@daikinindia.com
X