Skip to main content
Enquire Now

FCMF/FCVF-A Series

Cooling Only

FCMF/FCVF-A Series

Daikin’s FCF range of cassette air conditioners are designed to redefine air conditioning with 360⁰ airflow that cools the entire room to ensure comfort that never feels cold. Its revolutionary uniform air distribution guarantees comfort that spreads more widely. Besides this, the unit boasts of some of the amazing features that make it a perfect choice for summers.

Product Category

Available in (kW):

Salient Features

Auto restart

Auto restart

If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored.

D III net compatible

D III net compatible

Connection to a centralised control system is available without need for an optional adaptor. Available in Inverter Series only.

Drain pump mechanism

Drain pump mechanism

Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.

Energy consumption monitoring

Energy consumption  monitoring

Past power consumption is displayed for the current and previous days as well as in weekly and yearly intervals.

Humidity sensor

Humidity sensor

Not only temperature but also humidity is detected, and adjustments are made for comfortable air conditioning.

Individual air flow control

Individual air flow control

Airflow direction can be individually adjusted for each air discharge outlet to deliver optimal air distribution.

Night quiet operation

Night quiet operation

The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that.

Silver ION antibacterial drain pan

Silver ION antibacterial drain pan

A built-in anti-bacterial treatment that uses silver ion in the drain pan prevents the growth of bacteria, and mould that cause odours & clogging.

Swing pattern selection

Swing pattern selection

You can freely set air discharge settings by remote controller. One can choose from Standard setting, Draft prevention setting and Ceiling soiling prevention setting.

Specification

New Round Flow Cassette (Cooling Only)

inverter-5star-r32
Model Indoor unit FCMF50ARV16 FCMF71ARV16 FCMF90ARV16 FCMF100ARV16
Outdoor unit RZMF50BRV16 RZMF71BRV16 RZMF90BRV16 RZMF100BRV16
Remote Wireless Optional BRC4M150W16
Signal Receiver Unit -Model Number BRC7M632F-6
Wired Optional BRC1E63
Panel Code  Standard Without Sensing BYCQ125EAF6
Power supply      230V/50Hz/1ph 230V/50Hz/1ph 230V/50Hz/1ph 230V/50Hz/1ph
Cooling capacity -Rated (min ~max) kW 5.0 (3.2 ~5.6) 7.1 (3.2 ~8.0) 9.0 (4.5 ~10.1) 10.0 (5.0 ~11.2)
Power consumption Cooling-Rated kW 1.27 1.90 2.42 2.91
Annual Power Consumption kWh 744.87 1057.11 1365.2 1665.15
ISEER / Stars Wh/Wh 5.2 5.2 5.1 4.65
Indoor unit
Colour Galvanized Steel Plate
Airflow rate (H/HM/M/ML/L) m3/min 23 / 21 / 18.5 / 16 / 13.5 34.5 / 31 / 27.5 / 24 / 20
cfm 812/742/653/565/477 1218/1095/971/848/706
Sound level (H/HM/M/ML/L) dB(A) 37 / 34.5 / 32 / 29.5 / 27.5 45 / 41.5 / 38 / 35 / 32.5
Dimensions (HXWXD) Unit mm 256X840X840 298X840X840
Panel mm 50X950X950
Machine weight Unit kg 22 25
Panel kg 5.5
Colour     Ivory White
Outdoor unit
Compressor Type   Hermetically Sealed Swing Type
  Motor output kW 1.3 1.3 1.6 1.6
Refrigerant   R32
Refrigerant charge kg 1.09 1.3 2.8 2.8
Sound level Cooling dB(A) 48 50 51 51
Dimensions (HXWXD) mm 595x845x300 595x845x300 990x940x320 990x940x320
Machine weight kg 36.5 40 57 57
Certified operation range °CDB 21 ~ 48
Piping connections Liquid (Flare) mm 9.52
Gas (Flare) mm 15.88
Drain mm Dia 26 (Hole)
Max. interunit piping length   m 30 30 50 50
Max. installation level difference   m 20 20 30 30

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

New Round Flow Cassette (Cooling Only)

inverter-r32
Model Indoor unit FCMF125ARV16 FCMF125ARV16 FCMF140ARV16 FCMF140ARV16
Outdoor unit RZMF125BRV16 RZMF125BRY16 RZMF140BRV16 RZMF140BRY16
Remote Wireless Optional BRC4M150W16
Signal Receiver Unit -Model Number BRC7M632F-6
Wired Optional BRC1E63
Panel Code  Standard Without Sensing   BYCQ125EAF6
Power supply      230V/50Hz/1ph 400V/50Hz/3ph 230V/50Hz/1ph 400V/50Hz/3ph
Cooling capacity -Rated (min ~max) kW 12.5 (5.7 ~14.0) 12.5 (5.7 ~14.0) 14.0 (6.2 ~15.5) 14.0 (6.2 ~15.5)
Power consumption Cooling-Rated kW 4.60 4.225 5.80 5.30
Annual Power Consumption kWh NA
ISEER / Stars Wh/Wh NA
Indoor unit
Colour Galvanized Steel Plate
Airflow rate (H/HM/M/ML/L) m3/min 36.5 / 33 / 29 / 25 / 21
cfm 1288/1165/1024/883/742
Sound level (H/HM/M/ML/L) dB(A) 46 / 43 / 40 / 36 / 32.5
Dimensions (HXWXD) Unit mm 298X840X840
Panel mm 50X950X950
Machine weight Unit kg 25
Panel kg 5.5
Colour     Ivory White
Outdoor unit
Compressor Type   Hermetically Sealed Swing Type
Motor output kW 2.4 2.4 2.4 2.4
Refrigerant   R32
Refrigerant charge kg 3.1 3.1 3.1 3.1
Sound level Cooling dB(A) 55 55 55 55
Dimensions (HXWXD) mm 990x940x320 990x940x320 990x940x320 990x940x320
Machine weight kg 69 69 69 69
Certified operation range °CDB 21 ~ 48
Piping connections Liquid (Flare) mm 9.52
Gas (Flare) mm 15.88
Drain mm Dia 26 (Hole)
Max. interunit piping length   m 50 50 50 50
Max. installation level difference   m 30 30 30 30

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

Round Flow Ceiling Mounted Cassette Type (Cooling Only)

inverter-4star-r32
Model Indoor unit FCVF50ARV16 FCVF71ARV16 FCVF90ARV16 FCVF100ARV16
Outdoor unit RZVF50BRV16 RZVF71BRV16 RZVF90BRV16 RZVF100BRV16
Remote Wireless Optional BRC4M150W16
Signal Receiver Unit -Model Number BRC7M632F-6
Wired Optional BRC1E63
Panel Code  Without Sensing   BYCQ125EAF6
Power supply      230V/50Hz/1ph 230V/50Hz/1ph 230V/50Hz/1ph 230V/50Hz/1ph
Cooling capacity -Rated (min ~max) kW 5.0 (3.2 ~ 5.6) 7.1 (3.2 ~8.0) 9.0 (4.5 ~10.1) 10.0 (5.0 ~11.2)
Power consumption Cooling-Rated kW 1.52 2.235 2.58 3.16
Annual Power Consumption kWh 889.62 1264.11 1565.65 1839.63
ISEER / Stars Wh/Wh 4.35 4.35 4.45 4.21
Indoor unit
Colour Galvanized Steel Plate
Airflow rate (H/HM/M/ML/L) m3/min 23 / 21 / 18.5 / 16 / 13.5 34.5 / 31 / 27.5 / 24 / 20
cfm 812/742/653/565/477 1218/1095/971/848/706
Sound level (H/HM/M/ML/L) dB(A) 37 / 34.5 / 32 / 29.5 / 27.5 45 / 41.5 / 38 / 35 / 32.5
Dimensions (HXWXD) Unit mm 256X840X840 298X840X840
Panel mm 50X950X950
Machine weight Unit kg 22 25
Panel kg 5.5
Colour     Ivory White
Outdoor unit
Compressor Type   Hermetically Sealed Swing Type
  Motor output kW 1.3 1.3 1.6 1.6
Refrigerant   R32
Refrigerant charge kg 1.09 1.3 2.8 2.8
Sound level Cooling dB(A) 48 50 51 51
Dimensions (HXWXD) mm 595x845x300 595x845x300 990x940x320 990x940x320
Machine weight kg 36.5 40 57 57
Certified operation range °CDB 21 ~ 48
Piping connections Liquid (Flare) mm 9.52
Gas (Flare) mm 15.88
Drain mm Dia 26 (Hole)
Max. interunit piping length   m 30 30 50 50
Max. installation level difference   m 20 20 30 30

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

Round Flow Ceiling Mounted Cassette Type (Cooling Only)

inverter-r32
Model Indoor unit FCVF125ARV16 FCVF125ARV16 FCVF140ARV16 FCVF140ARV16
Outdoor unit RZVF125BRV16 RZVF125BRY16 RZVF140BRV16 RZVF140BRY16
Remote Wireless Optional BRC4M150W16
Signal Receiver Unit -Model Number BRC7M632F-6
Wired Optional BRC1E63
Panel Code  Standard Without Sensing   BYCQ125EAF6
Power supply      230V/50Hz/1ph 400V/50Hz/3ph 230V/50Hz/1ph 400V/50Hz/3ph
Cooling capacity -Rated (min ~max) kW 12.5 (5.7 ~14.0) 12.5 (5.7 ~14.0) 14.0 (6.2 ~15.5) 14.0 (6.2 ~15.5)
Power consumption Cooling-Rated kW 4.70 4.35 5.90 5.50
Annual Power Consumption kWh NA
ISEER / Stars Wh/Wh NA
Indoor unit
Colour Galvanized Steel Plate
Airflow rate (H/HM/M/ML/L) m3/min 36.5 / 33 / 29 / 25 / 21
cfm 1288/1165/1024/883/742
Sound level (H/HM/M/ML/L) dB(A) 46 / 43 / 40 / 36 / 32.5
Dimensions (HXWXD) Unit mm 298X840X840
Panel mm 50X950X950
Machine weight Unit kg 25
Panel kg 5.5
Colour     Ivory White
Outdoor unit
Compressor Type Hermetically Sealed Swing Type
Motor output kW 2.4 2.4 2.4 2.4
Refrigerant   R32
Refrigerant charge kg 3.1 3.1 3.1 3.1
Sound level Cooling dB(A) 55 55 55 55
Dimensions (HXWXD) mm 990x940x320 990x940x320 990x940x320 990x940x320
Machine weight kg 69 69 69 69
Certified operation range °CDB 21 ~ 48
Piping connections Liquid (Flare) mm 9.52
Gas (Flare) mm 15.88
Drain mm Dia 26 (Hole)
Max. interunit piping length   m 50 50 50 50
Max. installation level difference   m 30 30 30 30

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

AS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.

Customer Support Information: Give A Missed Call: @ 9210188999, Call Our Customer Contact Centre: 011-40319300 / 1860 180 3900 or Write To Us at: customerservice@daikinindia.com
X