Enquire Now

FCMF/FCVF-A Series

Cooling Only

Daikin’s FCF range of cassette air conditioners are designed to redefine air conditioning with 360⁰ airflow that cools the entire room to ensure comfort that never feels cold. Its revolutionary uniform air distribution guarantees comfort that spreads more widely. Besides this, the unit boasts of some of the amazing features that make it a perfect choice for summers.

Product category:

Available in (kW):

Salient Features

Auto restart

Auto-restart

If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored.

D III net compatible

Connection to a centralised control system is available without need for an optional adaptor. Available in Inverter Series only.

Drain pump mechanism

Drain pump mechanism

Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.

Energy consumption monitoring

Energy consumption monitoring

Past power consumption is displayed for the current and previous days as well as in weekly and yearly intervals.

Humidity sensor

Humidity sensor

Not only temperature but also humidity is detected, and adjustments are made for comfortable air conditioning.

Individual air flow control

Airflow direction can be individually adjusted for each air discharge outlet to deliver optimal air distribution.

Night quiet operation

Night quiet operation

The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that.

Silver ION antibacterial drain pan

Silver ION antibacterial drain pan

A built-in anti-bacterial treatment that uses silver ion in the drain pan prevents the growth of bacteria, and mould that cause odours & clogging.

Swing pattern selection

Swing pattern selection

You can freely set air discharge settings by remote controller. One can choose from Standard setting, Draft prevention setting and Ceiling soiling prevention setting.

Specification

New Round Flow Cassette (Cooling Only)

inverter-5star-r32
ModelIndoor unitFCMF50ARV16FCMF71ARV16FCMF90ARV16FCMF100ARV16
Outdoor unitRZMF50BRV16RZMF71BRV16RZMF90BRV16RZMF100BRV16
RemoteWirelessOptionalBRC4M150W16
Signal Receiver Unit -Model NumberBRC7M632F-6
WiredOptionalBRC1E63
Panel Code Standard Without SensingBYCQ125EAF6
Power supply   230V/50Hz/1ph230V/50Hz/1ph230V/50Hz/1ph230V/50Hz/1ph
Cooling capacity -Rated (min ~max)kW5.0 (3.2 ~5.6)7.1 (3.2 ~8.0)9.0 (4.5 ~10.1)10.0 (5.0 ~11.2)
Power consumptionCooling-RatedkW1.271.902.422.91
Annual Power ConsumptionkWh744.871057.111365.21665.15
ISEER / StarsWh/Wh5.25.25.14.65
Indoor unit
ColourGalvanized Steel Plate
Airflow rate (H/HM/M/ML/L)m3/min23 / 21 / 18.5 / 16 / 13.534.5 / 31 / 27.5 / 24 / 20
cfm812/742/653/565/4771218/1095/971/848/706
Sound level (H/HM/M/ML/L)dB(A)37 / 34.5 / 32 / 29.5 / 27.545 / 41.5 / 38 / 35 / 32.5
Dimensions (HXWXD)Unitmm256X840X840298X840X840
Panelmm50X950X950
Machine weightUnitkg2225
Panelkg5.5
Colour  Ivory White
Outdoor unit
CompressorType Hermetically Sealed Swing Type
 Motor outputkW1.31.31.61.6
Refrigerant R32
Refrigerant chargekg1.091.32.82.8
Sound levelCoolingdB(A)48505151
Dimensions (HXWXD)mm595x845x300595x845x300990x940x320990x940x320
Machine weightkg36.5405757
Certified operation range°CDB21 ~ 48
Piping connectionsLiquid (Flare)mm9.52
Gas (Flare)mm15.88
DrainmmDia 26 (Hole)
Max. interunit piping length m30305050
Max. installation level difference m20203030

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

New Round Flow Cassette (Cooling Only)

inverter-r32
ModelIndoor unitFCMF125ARV16FCMF125ARV16FCMF140ARV16FCMF140ARV16
Outdoor unitRZMF125BRV16RZMF125BRY16RZMF140BRV16RZMF140BRY16
RemoteWirelessOptionalBRC4M150W16
Signal Receiver Unit -Model NumberBRC7M632F-6
WiredOptionalBRC1E63
Panel Code Standard Without Sensing BYCQ125EAF6
Power supply   230V/50Hz/1ph400V/50Hz/3ph230V/50Hz/1ph400V/50Hz/3ph
Cooling capacity -Rated (min ~max)kW12.5 (5.7 ~14.0)12.5 (5.7 ~14.0)14.0 (6.2 ~15.5)14.0 (6.2 ~15.5)
Power consumptionCooling-RatedkW4.604.2255.805.30
Annual Power ConsumptionkWhNA
ISEER / StarsWh/WhNA
Indoor unit
ColourGalvanized Steel Plate
Airflow rate (H/HM/M/ML/L)m3/min36.5 / 33 / 29 / 25 / 21
cfm1288/1165/1024/883/742
Sound level (H/HM/M/ML/L)dB(A)46 / 43 / 40 / 36 / 32.5
Dimensions (HXWXD)Unitmm298X840X840
Panelmm50X950X950
Machine weightUnitkg25
Panelkg5.5
Colour  Ivory White
Outdoor unit
CompressorType Hermetically Sealed Swing Type
Motor outputkW2.42.42.42.4
Refrigerant R32
Refrigerant chargekg3.13.13.13.1
Sound levelCoolingdB(A)55555555
Dimensions (HXWXD)mm990x940x320990x940x320990x940x320990x940x320
Machine weightkg69696969
Certified operation range°CDB21 ~ 48
Piping connectionsLiquid (Flare)mm9.52
Gas (Flare)mm15.88
DrainmmDia 26 (Hole)
Max. interunit piping length m50505050
Max. installation level difference m30303030

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

Round Flow Ceiling Mounted Cassette Type (Cooling Only)

inverter-4star-r32
ModelIndoor unitFCVF50ARV16FCVF71ARV16FCVF90ARV16FCVF100ARV16
Outdoor unitRZVF50BRV16RZVF71BRV16RZVF90BRV16RZVF100BRV16
RemoteWirelessOptionalBRC4M150W16
Signal Receiver Unit -Model NumberBRC7M632F-6
WiredOptionalBRC1E63
Panel Code Without Sensing BYCQ125EAF6
Power supply   230V/50Hz/1ph230V/50Hz/1ph230V/50Hz/1ph230V/50Hz/1ph
Cooling capacity -Rated (min ~max)kW5.0 (3.2 ~ 5.6)7.1 (3.2 ~8.0)9.0 (4.5 ~10.1)10.0 (5.0 ~11.2)
Power consumptionCooling-RatedkW1.522.2352.583.16
Annual Power ConsumptionkWh889.621264.111565.651839.63
ISEER / StarsWh/Wh4.354.354.454.21
Indoor unit
ColourGalvanized Steel Plate
Airflow rate (H/HM/M/ML/L)m3/min23 / 21 / 18.5 / 16 / 13.534.5 / 31 / 27.5 / 24 / 20
cfm812/742/653/565/4771218/1095/971/848/706
Sound level (H/HM/M/ML/L)dB(A)37 / 34.5 / 32 / 29.5 / 27.545 / 41.5 / 38 / 35 / 32.5
Dimensions (HXWXD)Unitmm256X840X840298X840X840
Panelmm50X950X950
Machine weightUnitkg2225
Panelkg5.5
Colour  Ivory White
Outdoor unit
CompressorType Hermetically Sealed Swing Type
 Motor outputkW1.31.31.61.6
Refrigerant R32
Refrigerant chargekg1.091.32.82.8
Sound levelCoolingdB(A)48505151
Dimensions (HXWXD)mm595x845x300595x845x300990x940x320990x940x320
Machine weightkg36.5405757
Certified operation range°CDB21 ~ 48
Piping connectionsLiquid (Flare)mm9.52
Gas (Flare)mm15.88
DrainmmDia 26 (Hole)
Max. interunit piping length m30305050
Max. installation level difference m20203030

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

Round Flow Ceiling Mounted Cassette Type (Cooling Only)

inverter-r32
ModelIndoor unitFCVF125ARV16FCVF125ARV16FCVF140ARV16FCVF140ARV16
Outdoor unitRZVF125BRV16RZVF125BRY16RZVF140BRV16RZVF140BRY16
RemoteWirelessOptionalBRC4M150W16
Signal Receiver Unit -Model NumberBRC7M632F-6
WiredOptionalBRC1E63
Panel Code Standard Without Sensing BYCQ125EAF6
Power supply   230V/50Hz/1ph400V/50Hz/3ph230V/50Hz/1ph400V/50Hz/3ph
Cooling capacity -Rated (min ~max)kW12.5 (5.7 ~14.0)12.5 (5.7 ~14.0)14.0 (6.2 ~15.5)14.0 (6.2 ~15.5)
Power consumptionCooling-RatedkW4.704.355.905.50
Annual Power ConsumptionkWhNA
ISEER / StarsWh/WhNA
Indoor unit
ColourGalvanized Steel Plate
Airflow rate (H/HM/M/ML/L)m3/min36.5 / 33 / 29 / 25 / 21
cfm1288/1165/1024/883/742
Sound level (H/HM/M/ML/L)dB(A)46 / 43 / 40 / 36 / 32.5
Dimensions (HXWXD)Unitmm298X840X840
Panelmm50X950X950
Machine weightUnitkg25
Panelkg5.5
Colour  Ivory White
Outdoor unit
CompressorTypeHermetically Sealed Swing Type
Motor outputkW2.42.42.42.4
Refrigerant R32
Refrigerant chargekg3.13.13.13.1
Sound levelCoolingdB(A)55555555
Dimensions (HXWXD)mm990x940x320990x940x320990x940x320990x940x320
Machine weightkg69696969
Certified operation range°CDB21 ~ 48
Piping connectionsLiquid (Flare)mm9.52
Gas (Flare)mm15.88
DrainmmDia 26 (Hole)
Max. interunit piping length m50505050
Max. installation level difference m30303030

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

AS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.

Customer Support Information: Give A Missed Call: @ 9210188999, Call Our Customer Contact Centre: 011-40319300or Write To Us at: customerservice@daikinindia.com