The series offers a wide range of advanced features designed to benefit all stakeholders in the air‑conditioning ecosystem, including building owners, consultants, installers, and facility management teams. It supports both cooling and heating through a single VRV system, ensuring greater flexibility and convenience. With its newly engineered casing, the series delivers a single module of up to 26 class while achieving significant energy savings through enhanced technology. Its performance has been optimized in all aspects by incorporating innovative concepts, cutting‑edge technologies, and a comprehensive set of functions that improve design flexibility, simplify installation, and enhance overall reliability.

Product Category
Model
VRV Alpha

Salient Features

New Casing​

New Casing​

Energy Savings​

Energy Savings​

Design Flexibility​

Design Flexibility​

Easy Installation​

Easy Installation​

Reliability & Comfort​

Reliability & Comfort​

Specification

vrv alpha(Cooling only)

 
MODELRXQ6BRY16RXQ8BRY16RXQ10BRY16RXQ12BRY16RXQ14BRY16RXQ16BRY16
Combination units------
Power supply3 Phase, 50 Hz, 380–415 V
Cooling capacityBtu/h54,60076,40095,500114,000136,000154,000
kW1622.42833.54045
ISEERw/w10.909.6611.4410.818.678.47
Capacity control%11–10011–10013–10012–10011–1009–100
CompressorTypeHermetically Sealed Scroll Type
No. of compressor1
Airflow ratem3/min158158174185237266
Dimensions (H×W×D)mm1660 × 930 × 7651660 × 1240 × 765
Machine weightkg195195202202240262
Sound leveldB(A)565659596163
Operation
range
Cooling°CDB10 ~ 55
RefrigerantType R410A
Chargekg7.17.27.47.59.610.0
Piping
connections
Liquidmmø 9.5ø 12.7
Gasmmø 19.1ø 22.2ø 28.6

Note :

Specifications are based on tde following conditions::

  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping lengtd: 7.5 m, Level difference: 0
  • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of tde unit at a height of 1.5 m. During actual operation, tdese values are normally somewhat higher as a result of ambient conditions.
  • (ES) for anticorrosion treated outdoor unit.

vrv alpha(Cooling only)

 
MODELRXQ18BRY16RXQ20BRY16RXQ22BRY16RXQ24BRY16RXQ26BRY16RXQ28BRY16RXQ30BRY16RXQ32BRY16
Combination units-----RXQ14BRY16 RXQ14BRY16RXQ12BRY16 RXQ18BRY16RXQ14BRY16 RXQ18BRY16
Power supply3 Phase, 50Hz, 380–415 V
Cooling capacityBtu/h171000191000210000229000249000273000285000307000
kW505661.5677380.083.590
ISEERw/w8.568.389.098.888.428.679.698.57
Capacity control%8–1008–1008–1008–1008–1005–1005–1005–100
CompressorTypeHermetically Sealed Scroll Type
No. of compressor11+1
Airflow ratem3/min266306430430411237+237185+266237+266
Dimensions (H×W×D)mm1660 × 1240 × 7651660 × 1750 × 765(1660 × 1240 × 765) + (1660 × 1240 × 765)(1660 × 930 × 765) + (1660 × 1240 × 765)(1660 × 1240 × 765) + (1660 × 1240 × 765)
Machine weightkg262285324324350240+240202+262240+262
Sound leveldB(A)6466676868656566
Operation
range
Cooling°CDB10 ~ 55
RefrigerantType R410A
Chargekg10.111.711.711.711.79.6 + 9.67.5 + 10.19.6 + 10.1
Piping
connections
Liquidmmø 15.9ø 19.1
Gasmmø 28.6ø 34.9ø 34.9

Note :

Specifications are based on tde following conditions::

  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping lengtd: 7.5 m, Level difference: 0
  • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of tde unit at a height of 1.5 m. During actual operation, tdese values are normally somewhat higher as a result of ambient conditions.
  • (ES) for anticorrosion treated outdoor unit.

vrv alpha(Cooling only)

 
MODELRXQ34BRY16RXQ36BRY16RXQ38BRY16RXQ40BRY16RXQ42BRY16RXQ44BRY16
Combination unitsRXQ16BRY16 RXQ18BRY16RXQ18BRY16 RXQ18BRY16RXQ14BRY16 RXQ24BRY16RXQ14BRY16 RXQ26BRY16RXQ18BRY16 RXQ24BRY16RXQ18BRY16 RXQ26BRY16
Power supply3 Phase, 50Hz, 380–415 V
Cooling capacityBtu/h324000341000365000386000399000420000
kW95100107113117123
ISEERw/w8.508.348.778.458.738.63
Capacity control%4–1004–1004–1004–1004–1004–100
CompressorTypeHermetically Sealed Scroll Type
No. of compressor1 + 1
Airflow ratem3/min266 + 266266 + 266237 + 430237 + 411266 + 430266 + 411
Dimensions (H×W×D)mm(1660 × 1240 × 765) + (1660 × 1240 × 765)(1660 × 1240 × 765) + (1660 × 1240 × 765)(1660 × 1240 × 765) + (1660 × 1750 × 765)
Machine weightkg262 + 262262 + 262240 + 324240 + 350262 + 324262 + 350
Sound leveldB(A)676869697070
Operation
range
Cooling°CDB10 ~ 55
RefrigerantType R410A
Chargekg10.1 + 10.110.1 + 10.19.6 + 11.79.6 + 11.710.1 + 11.710.1 + 11.7
Piping
connections
Liquidmmø 19.1
Gasmmø 41.3

Note :

Specifications are based on tde following conditions::

  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping lengtd: 7.5 m, Level difference: 0
  • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of tde unit at a height of 1.5 m. During actual operation, tdese values are normally somewhat higher as a result of ambient conditions.
  • (ES) for anticorrosion treated outdoor unit.

vrv alpha(Cooling only)

  
MODELRXQ46BRY16RXQ48BRY16RXQ50BRY16RXQ52BRY16RXQ54BRY16RXQ56BRY16RXQ58BRY16RXQ60BRY16
Combination unitsRXQ22BRY16 RXQ24BRY16RXQ24BRY16 RXQ24BRY16RXQ24BRY16 RXQ26BRY16RXQ26BRY16 RXQ26BRY16RXQ18BRY16 RXQ18BRY16 RXQ18BRY16RXQ12BRY16 RXQ18BRY16 RXQ26BRY16RXQ14BRY16 RXQ18BRY16 RXQ26BRY16RXQ18BRY16 RXQ18BRY16 RXQ24BRY16
Power supply3 Phase, 50Hz, 380–415 V
Cooling capacityBtu/h440000457000478000498000512000532000556000570000
kW129134140146150156163167
ISEERw/w8.398.718.638.418.459.278.558.38
Capacity control%4–1004–1004–1004–1003–1003–1003–1002–100
CompressorTypeHermetically Sealed Scroll Type
No. of compressor1 + 11 + 1 + 1
Airflow ratem3/min430 + 430430 + 430430 + 411411 + 411266 + 266 + 266185 + 266 + 411237 + 266 + 411266 + 266 + 430
Dimensions (H×W×D)mm(1660 × 1750 × 765) + (1660 × 1750 × 765)(1660 × 1750 × 765) + (1660 × 1750 × 765)(1660 × 1750 × 765) + (1660 × 1750 × 765)(1660 × 1240 × 765) × 3(1660 × 930 × 765) + (1660 × 1240 × 765) + (1660 × 1750 × 765)(1660 × 1240 × 765) + (1660 × 1240 × 765) + (1660 × 1750 × 765)(1660 × 1240 × 765) + (1660 × 1240 × 765) + (1660 × 1750 × 765)
Machine weightkg324 + 324324 + 324324 + 350350 + 350262 + 262 + 262202 + 262 + 350240 + 262 + 350262 + 262 + 324
Sound leveldB(A)7172727269707171
Operation
range
Cooling°CDB10 ~ 55
RefrigerantType R410A
Chargekg11.7 + 11.711.7 + 11.711.7 + 11.711.7 + 11.710.1 + 10.1 + 10.17.5 + 10.1 + 11.79.6 + 10.1 + 11.710.1 + 10.1 + 11.7
Piping
connections
Liquidmmø 19.1
Gasmmø 41.3

Note :

Specifications are based on tde following conditions::

  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping lengtd: 7.5 m, Level difference: 0
  • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of tde unit at a height of 1.5 m. During actual operation, tdese values are normally somewhat higher as a result of ambient conditions.
  • (ES) for anticorrosion treated outdoor unit.

vrv alpha(Cooling only)

 
MODELRXQ62BRY16RXQ64BRY16RXQ66BRY16RXQ68BRY16RXQ70BRY16RXQ72BRY16
Combination unitsRXQ18BRY16 RXQ18BRY16 RXQ26BRY16RXQ12BRY16 RXQ26BRY16 RXQ26BRY16RXQ18BRY16 RXQ24BRY16 RXQ24BRY16RXQ18BRY16 RXQ24BRY16 RXQ26BRY16RXQ18BRY16 RXQ26BRY16 RXQ26BRY16RXQ24BRY16 RXQ24BRY16 RXQ24BRY16
Power supply3 Phase, 50Hz, 380–415 V
Cooling capacityBtu/h590000611000628000648000669000684000
kW173179184190196201
ISEERw/w8.619.228.368.588.528.36
Capacity control%2–1002–1002–1002–1002–1003–100
CompressorTypeHermetically Sealed Scroll Type
No. of compressor1 + 1 + 1
Airflow ratem3/min266 + 266 + 430185 + 411 + 411266 + 430 + 430266 + 430 + 411261 + 411 + 411430 + 430 + 430
Dimensions (H×W×D)mm(1660×1240×765) + (1660×1240×765) + (1660×1750×765)(1660×930×765) + (1660×1750×765) + (1660×1750×765)(1660×1240×765) + (1660×1750×765) + (1660×1750×765)(1660×1240×765) + (1660×1750×765) + (1660×1750×765)(1660×1240×765) + (1660×1750×765) + (1660×1750×765)(1660×1750×765) + (1660×1750×765) + (1660×1750×765)
Machine weightkg262 + 262 + 350202 + 350 + 350262 + 324 + 324262 + 324 + 350262 + 350 + 350324 + 324 + 324
Sound leveldB(A)717272727273
Operation
range
Cooling°CDB10 ~ 55
RefrigerantType R410A
Chargekg10.1 + 10.1 + 11.77.5 + 11.7 + 11.710.1 + 11.7 + 11.710.1 + 11.7 + 11.710.1 + 11.7 + 11.711.7 + 11.7 + 11.7
Piping
connections
Liquidmmø 19.1
Gasmmø 41.3

Note :

Specifications are based on tde following conditions::

  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping lengtd: 7.5 m, Level difference: 0
  • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of tde unit at a height of 1.5 m. During actual operation, tdese values are normally somewhat higher as a result of ambient conditions.
  • (ES) for anticorrosion treated outdoor unit.

vrv alpha(Cooling only)

 
MODELRXQ74BRY16RXQ76BRY16RXQ78BRY16
Combination unitsRXQ24BRY16 RXQ24BRY16 RXQ26BRY16RXQ24BRY16 RXQ26BRY16 RXQ26BRY16RXQ26BRY16 RXQ26BRY16 RXQ26BRY16
Power supply3 Phase, 50Hz, 380–415 V
Cooling capacityBtu/h706000727000747000
kW207213219
ISEERw/w8.568.558.40
Capacity control%3–1003–1003–100
CompressorTypeHermetically Sealed Scroll Type
No. of compressor1 + 1 + 1
Airflow ratem3/min430 + 430 + 411430 + 411 + 411411 + 411 + 411
Dimensions (H×W×D)mm(1660×1750×765) + (1660×1750×765) + (1660×1750×765)(1660×1750×765) + (1660×1750×765) + (1660×1750×765)(1660×1750×765) + (1660×1750×765) + (1660×1750×765)
Machine weightkg324 + 324 + 350324 + 350 + 350350 + 350 + 350
Sound leveldB(A)737373
Operation
range
Cooling°CDB10 ~ 55
RefrigerantType R410A
Chargekg11.7 + 11.7 + 11.711.7 + 11.7 + 11.711.7 + 11.7 + 11.7
Piping
connections
Liquidmmø 22.2
Gasmmø 41.3

Note :

Specifications are based on tde following conditions::

  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping lengtd: 7.5 m, Level difference: 0
  • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of tde unit at a height of 1.5 m. During actual operation, tdese values are normally somewhat higher as a result of ambient conditions.
  • (ES) for anticorrosion treated outdoor unit.

vrv alpha(Heat Pump)

 
MODELRXYQ6BRY16RXYQ8BRY16RXYQ10BRY16RXYQ12BRY16RXYQ14BRY16RXYQ16BRY16
Combination units
Power supply3 PHASE, 50Hz, 380-415 V
Cooling capacityBtu/h546007640095500114000136000154000
kW1622.42833.54045
Heating capacityBtu/h6140085300107000128000154000171000
kW18.025.031.537.545.050.0
ISEERw/w10.909.6611.4010.818.678.47
Capacity control%11-10011-10013-10012-1007-1006-100
CompressorTypeHermetically Sealed Scroll Type
No. of compressors11+1
Airflow ratem3/min155155169181260266
Dimensions (H×W×D)mm1660 × 930 × 7651660 × 1240 × 765
Machine weightkg210210220220305305
Sound level (C/H)dBA56/5656/5657/5860/6261/6161/61
Operation rangeCooling°CDB-5 ~ 55
Heating°CWB-25 ~ 15.5
RefrigerantType R410A
Chargekg6.86.97.17.29.79.9
Piping connectionsLiquidmmØ 9.5Ø 12.7
GasmmØ 19.1Ø 22.2Ø 28.6

Note :

Specifications are based on tde following conditions::

  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping lengtd: 7.5 m, Level difference: 0
  • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of tde unit at a height of 1.5 m. During actual operation, tdese values are normally somewhat higher as a result of ambient conditions.
  • (ES) for anticorrosion treated outdoor unit.

vrv alpha(Heat Pump)

  
MODELRXYQ18BRY16RXYQ20BRY16RXYQ22BRY16RXYQ24BRY16RXYQ26BRY16RXYQ28BRY16
Combination unitsRXYQ12BRY16
RXYQ16BRY16
-
Power supply3 PHASE, 50Hz, 380-415 V
Cooling capacityBtu/h171000191000210000229000249000268000
kW505661.5677378.5
Heating capacityBtu/h191000215000235000249000249000299000
kW56.063.069.073.07387.5
ISEERw/w8.568.389.098.887.779.32
Capacity control%5-1005-1006-1006-1006-1004-100
CompressorTypeHermetically Sealed Scroll Type
No. of compressors1+12+1
Airflow ratem3/min258306430430430181+266
Dimensions (H×W×D)mm1660 × 1240 × 7651660 × 1750 × 765(1660 × 1240 × 765)
+ (1660 × 930 × 765)
Machine weightkg335335380380380220 + 305
Sound level (C/H)dBA61/6165/6667/6768/6868/6864/65
Operation rangeCooling°CDB-5 ~ 55
Heating°CWB-25 ~ 15.5
RefrigerantType R410A
Chargekg11.711.711.711.711.77.2 + 9.9
Piping connectionsLiquidmmØ 15.9Ø 19.1
GasmmØ 28.6Ø 34.9

Note :

Specifications are based on tde following conditions::

  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping lengtd: 7.5 m, Level difference: 0
  • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of tde unit at a height of 1.5 m. During actual operation, tdese values are normally somewhat higher as a result of ambient conditions.
  • (ES) for anticorrosion treated outdoor unit.

vrv alpha(Heat Pump)

 
MODELRXYQ30BRY16RXYQ32BRY16RXYQ34BRY16RXYQ36BRY16RXYQ38BRY16RXYQ40BRY16
Combination unitsRXYQ12BRY16
RXYQ18BRY16
-
RXYQ12BRY16
RXYQ20BRY16
-
RXYQ12BRY16
RXYQ22BRY16
-
RXYQ12BRY16
RXYQ24BRY16
-
RXYQ12BRY16
RXYQ26BRY16
-
RXYQ20BRY16
RXYQ20BRY16
-
Power supply3 PHASE, 50Hz, 380-415 V
Cooling capacityBtu/h285000305000324000341000362000382000
kW83.589.595100106112
Heating capacityBtu/h319000341000362000375000375000430000
kW93.5100106110110126
ISEERw/w9.339.159.969.849.298.38
Capacity control%3 - 1003 - 1003 - 1004 - 1004 - 1003 - 100
CompressorTypeHermetically Sealed Scroll Type
No. of compressors2+12+2
Airflow ratem3/min181+258181+306430+181181+430181+430306+306
Dimensions (H×W×D)mm(1660 × 1240 × 765) + (1660 × 930 × 765)(1660 × 1750 × 765) + (1660 × 930 × 765)(1660 × 1240 × 765) + (1660 × 1240 × 765)
Machine weightkg220 + 335220 + 335220 + 380220 + 380335 + 335335 + 335
Sound level (C/H)dBA64/6566/6768/6869/6969/6968/69
Operation rangeCooling°CDB-5 ~ 55
Heating°CWB-25 ~ 15.5
RefrigerantType R410A
Chargekg7.2+11.77.2+11.77.2+11.77.2+11.77.2+11.711.7+11.7
Piping connectionsLiquidmmØ 19.1
GasmmØ 34.9Ø 41.3

Note :

Specifications are based on tde following conditions::

  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping lengtd: 7.5 m, Level difference: 0
  • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of tde unit at a height of 1.5 m. During actual operation, tdese values are normally somewhat higher as a result of ambient conditions.
  • (ES) for anticorrosion treated outdoor unit.

vrv alpha(Heat Pump)

 
MODELRXYQ42BRY16RXYQ44BRY16RXYQ46BRY16RXYQ48BRY16RXYQ50BRY16RXYQ52BRY16
Combination unitsRXYQ16BRY16
RXYQ26BRY16
-
RXYQ20BRY16
RXYQ24BRY16
-
RXYQ20BRY16
RXYQ26BRY16
-
RXYQ22BRY16
RXYQ26BRY16
-
RXYQ24BRY16
RXYQ26BRY16
-
RXYQ26BRY16
RXYQ26BRY16
-
Power supply3 PHASE, 50Hz, 380-415 V
Cooling capacityBtu/h403000420000440000457000478000498000
kW118123129134140146
Heating capacityBtu/h420000464000464000485000498000498000
kW123136.0136.0142146146
ISEERw/w8.128.638.018.318.267.76
Capacity control%3 - 1002 - 1002 - 1003 - 1003 - 1003 - 100
CompressorTypeHermetically Sealed Scroll Type
No. of compressors2+2
Airflow ratem3/min266+430306+430430+306430+430430+430430+430
Dimensions (H×W×D)mm(1660 × 1240 × 765) + (1660 × 1750 × 765)(1660 × 1750 × 765) + (1660 × 1750 × 765)
Machine weightkg305 + 380335 + 380380 + 335380 + 380380 + 380380 + 380
Sound level (C/H)dBA69/6971/7170/7071/7171/7171/71
Operation rangeCooling°CDB-5 ~ 55
Heating°CWB-25 ~ 15.5
RefrigerantType R410A
Chargekg11.7 + 9.911.7 + 11.711.7 + 11.711.7 + 11.711.7 + 11.711.7 + 11.7
Piping connectionsLiquidmmØ 19.1
GasmmØ 41.3

Note :

Specifications are based on tde following conditions::

  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping lengtd: 7.5 m, Level difference: 0
  • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of tde unit at a height of 1.5 m. During actual operation, tdese values are normally somewhat higher as a result of ambient conditions.
  • (ES) for anticorrosion treated outdoor unit.

vrv alpha(Heat Pump)

 
MODELRXYQ54BRY16RXYQ56BRY16RXYQ58BRY16RXYQ60BRY16RXYQ62BRY16RXYQ64BRY16
Combination unitsRXYQ12BRY16 RXYQ26BRY16RXYQ12BRY16 RXYQ24BRY16RXYQ12BRY16 RXYQ26BRY16RXYQ12BRY16 RXYQ24BRY16 RXYQ24BRY16RXYQ12BRY16 RXYQ24BRY16 RXYQ26BRY16RXYQ12BRY16 RXYQ26BRY16 RXYQ26BRY16
Power supply3-phase, 380–415 V, 50 Hz
Cooling capacityBtu/h510,000532,000553,000570,000590,000611,000
kW151156162167173179
Heating capacityBtu/h546,000590,000590,000624,000624,000624,000
kW160167173183183183
ISEERw/w9.009.368.999.529.158.78
Capacity control%2~1002~1002~1002~1003~1003~100
CompressorTypeHermetically Sealed Scroll Type
No. of compressor1 + 2 + 2
Airflow ratem3/min181+266+430169+430+306181+430+306181+430+430181+430+430181+430+430
Dimensions (H×W×D)mm(1660×930×765)+(1660×1240×765)+(1660×1750×765)(1660×930×765)+(1660×1750×765)+(1660×1750×765)
Machine weightkg220+305+380220+335+380220+335+380220+380+380220+380+380220+380+380
Sound level (C/H)dB(A)69/7070/7170/7171/7271/7271/72
Operation rangeCooling°CDB-5 ~ 55
RefrigerantType R410A
Chargekg7.2+9.9+11.77.1+11.7+11.77.2+11.7+11.77.2+11.7+11.77.2+11.7+11.77.2+11.7+11.7
Piping connectionsLiquidmmØ 19.1
GasmmØ 41.3

Note :

Specifications are based on tde following conditions::

  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping lengtd: 7.5 m, Level difference: 0
  • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of tde unit at a height of 1.5 m. During actual operation, tdese values are normally somewhat higher as a result of ambient conditions.
  • (ES) for anticorrosion treated outdoor unit.

vrv alpha(Heat Pump)

 
MODELRXYQ66BRY16RXYQ68BRY16RXYQ70BRY16RXYQ72BRY16RXYQ74BRY16RXYQ76BRY16RXYQ78BRY16
Combination unitsRXYQ20BRY16 RXYQ20BRY16 RXYQ26BRY16RXYQ16BRY16 RXYQ26BRY16 RXYQ26BRY16RXYQ20BRY16 RXYQ24BRY16 RXYQ26BRY16RXYQ20BRY16 RXYQ26BRY16 RXYQ26BRY16RXYQ22BRY16 RXYQ26BRY16 RXYQ26BRY16RXYQ24BRY16 RXYQ26BRY16 RXYQ26BRY16RXYQ26BRY16 RXYQ26BRY16 RXYQ26BRY16
Power supply3 PHASE, 50Hz , 380-415 V
Cooling capacityBtu/h631,000652,000669,000689,000706,000727,000747,000
kW185191196202207213219
Heating capacityBtu/h679,000669,000713,000713,000734,000747,000747,000
kW199196209209215219219
ISEERw/w8.098.048.267.888.078.087.75
Capacity control%2~1002~1002~1002~1002~1002~1002~100
CompressorTypeHermetically Sealed Scroll Type
No. of compressor2 + 2 + 2
Airflow ratem3/min306+306+430266+430+430306+430+430306+430+430430+430+430430+430+430430+430+430
Dimensions (H×W×D)mm(1660×1240×765)+(1660×1240×765)+(1660×1750×765)(1660×1240×765)+(1660×1750×765)+(1660×1750×765)(1660×1750×765)+(1660×1750×765)+(1660×1750×765)
Machine weightkg335+335+380305+380+380335+380+380335+380+380380+380+380380+380+380380+380+380
Sound level (C/H)dB(A)71/7271/7171/7171/7169/7069/7069/70
Operation rangeCooling°CDB-5 ~ 55
RefrigerantType R410A
Chargekg11.7+11.7+11.79.9+11.7+11.711.7+11.7+11.711.7+11.7+11.711.7+11.7+11.711.7+11.7+11.711.7+11.7+11.7
Piping connectionsLiquidmmØ 19.1Ø 22.2
GasmmØ 41.3

Note :

Specifications are based on tde following conditions::

  • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping lengtd: 7.5 m, Level difference: 0
  • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of tde unit at a height of 1.5 m. During actual operation, tdese values are normally somewhat higher as a result of ambient conditions.
  • (ES) for anticorrosion treated outdoor unit.

AS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.

Customer Support Information: WhatsApp us your query @ 9871409300. Call Our Customer Contact Centre: 011-40319300 / 1860 180 3900 or Write To Us at customerservice@daikinindia.com

X
Popup Image
//